Windmill Cables
NTSCGEWOEU Medium Voltage Torsion Resistant Cable |
|
Standards
DIN VDE 0250 Part 813
Construction
Conductor:Stranded tinned copper, class 5 according to DIN VDE 0295/IEC 60228.
Inner Conductor Layer: Semiconductive rubber compound.
Insulation: Heat resistant EPR.
Outer Conductor Layer: Semiconductive rubber compound.
Sheath: Heat and cold resistant special rubber compound based on CM (Chlorinated synthetic rubber) or CR (Chloroprene rubber).
Dimensions and Weight
12/20kV
Construction |
Nominal Overall Diameter |
Nominal Weight |
No. of cores×mm² |
mm |
kg/km |
3×25/25 |
61.2 |
4780 |
3×35/35 |
65.9 |
5700 |
3×50/50 |
69.5 |
6630 |
3×70/70 |
73.5 |
7840 |
18/30kV
Construction |
Nominal Overall Diameter |
Nominal Weight |
No. of cores×mm² |
mm |
kg/km |
3×25/25 |
79.1 |
7520 |
3×35/35 |
80.5 |
8050 |
3×50/50 |
83.1 |
8920 |
3×70/70 |
89.0 |
10600 |
20/35kV
Construction |
Nominal Overall Diameter |
Nominal Weight |
No. of cores×mm² |
mm |
kg/km |
3×25/25 |
86.2 |
8820 |
3×35/35 |
90.8 |
10000 |
3×50/50 |
93.0 |
10830 |
3×70/70 |
96.1 |
12050 |
|
|
|
|
|
|
|